Myopia Research - Treatment, Prevention, Causes, Correction

Myopia Research Today is a free monthly online journal that collates and summarizes the latest research about Myopia, including details on treatment, prevention, causes, correction.


Myopia Research Today

Home

View Latest Issue

Information About Myopia

Books on Myopia

Advertising in Research Today

View Other Research Today Publications



Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography.

Kohnen T, Cichocki M, Koss MJ

Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. kohnen@em.uni-frankfurt.de

PURPOSE: To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS: One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Ophtec BV) was implanted in 45 eyes of 26 patients with myopia or myopic astigmatism. The central distance between the pIOL and corneal endothelium and between the pIOL and anterior surface of the crystalline lens was evaluated using Scheimpflug photography 6 and 12 months after surgery. RESULTS: The mean preoperative spherical equivalent was -9.32 diopters +/- 1.78 (SD) (range -6.5 to -13.5 D). Each IOL model was implanted in 15 eyes. The median distance from the central corneal endothelium to the anterior surface of the pIOL at 6 months and 12 months was 2.65 mm and 2.64 mm, respectively, in the Artisan group, 2.47 mm and 2.50 mm, respectively, in the Artiflex I group, and 2.48 mm and 2.52 mm, respectively, in the Artiflex II group. The median distance between the posterior surface of the pIOL and the anterior surface of the crystalline lens at 6 months and 12 months was 0.40 mm and 0.48 mm, respectively, in the Artisan group, 0.53 mm and 0.55 mm, respectively, in the Artiflex I group, and 0.68 mm and 0.66 mm, respectively, in the Artiflex II group. At 12 months, the distance between the pIOL and crystalline lens was statistically significantly greater in the Artiflex II group than in the Artisan group (P<.01). CONCLUSION: The intraocular position of rigid pIOLs and foldable silicone iris-supported pIOLs showed a difference between the 3 pIOL models in space to the crystalline lens and the corneal endothelium, which may affect long-term results in terms of IOL interaction with surrounding tissue.

Published 31 December 2007 in J Cataract Refract Surg, 34(1): 114-20.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Myopia Research Today. All Rights Reserved.



Myopia Research Today Archive:

Volume 1 (2004)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Myopia Books

The Art of LASIK

The Art of LASIK