The effect of hinge position and depth plate on the rate of recovery of corneal sensation following LASIK.

Nassaralla BA, McLeod SD, Boteon JE, Nassaralla JJ

Goiania Eye Institute, Goiania, Goias, Brazil. nassaral@zaz.com.br

PURPOSE: To evaluate and compare the effect of hinge position and flap thickness on recovery rate of corneal sensation after (LASIK). DESIGN: Prospective, randomized clinical study. METHODS: Forty eyes of 40 patients underwent LASIK to correct myopia ranging from -1.00 to -2.50 diopters. Corneal sensitivity was measured preoperatively and each month after surgery until recovery to preoperative level. The nasal-hinged ACS microkeratome (NH) with depth plates of 130 and 160 microm and the superior-hinged Hansatome microkeratome (SH) with depth plates of 160 and 180 microm were used for corneal flap creation. The eyes were divided into four groups according to the hinge position and depth plate (DP): group 1, NH and 130 microm DP; group 2, NH and 160 microm DP; group 3, SH and 160 microm DP; group 4, SH and 180 microm DP. RESULTS: Corneal sensitivity returned to preoperative level after 3.7 (+/- 0.4), 4.4 (+/- 0.6), 5.4 (+/- 0.8), and 5.8 (+/- 0.9) months, respectively, in groups 1, 2, 3, and 4. Statistically significant differences were found between groups 1 and 2, but not between groups 3 and 4. Corneal sensitivity gradually returned to preoperative levels in all groups. Sensitivity of the hinge area was higher than other areas at every time point. CONCLUSIONS: The results suggest that after LASIK, hinge position and flap thickness seem to be important factors in the rate of return of corneal sensitivity. A thin flap with a nasally placed hinge is associated with the most rapid recovery of corneal sensitivity.

Published 17 January 2005 in Am J Ophthalmol, 139(1): 118-24.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Myopia Research Today. All Rights Reserved.



Myopia Research Today Archive:

Volume 1 (2004)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Myopia Books

Management of Complications in Refractive Surgery

Management of Complications in Refractive Surgery