Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry.

Wirbelauer C, Pham DT

Klinik für Augenheilkunde, Vivantes Klinikum Neukölln, Berlin, Germany. christopher.wirbelauer@vivantes.de

PURPOSE: To assess the continuous intraoperative monitoring of central corneal thickness (CCT) changes during laser in situ keratomileusis (LASIK) using online optical coherence pachymetry (OCP). SETTING: Department of Ophthalmology, Vivantes Klinikum Neukolln, Berlin, Germany. METHODS: In this prospective nonrandomized comparative clinical case series of consecutive patients, 32 eyes having LASIK for myopia, myopic astigmatism, or hyperopia were continuously monitored intraoperatively in real time with online OCP integrated into a clinical excimer laser. The intraoperative values were compared to the postoperative flap and residual stromal thicknesses measured with corneal optical coherence tomography (OCT) as well as the calculated myopic ablation depth. RESULTS: Continuous monitoring with online OCP enabled intraoperative visualization of the CCT changes during LASIK. The CCT, flap thickness after the microkeratome pass, time-resolved ablation, and residual stromal thickness were assessed. Intraoperatively, the mean flap thickness was 135 microm +/- 38 (SD) and the mean residual stromal thickness, 286 +/- 59 microm. The mean intraoperative flap and residual stromal thickness values were 43.7 microm and 15.4 microm lower, respectively, than the postoperative values assessed with corneal OCT (P<.001 and P=.005, respectively). The optically determined myopic ablation depth was 118 +/- 37 microm, which was 28 microm higher than the nominal ablation depth. There was a significant correlation (P<.001) between the postoperative flap (r=0.79) and residual (r=0.88) thickness measured with corneal OCT as well as the calculated myopic ablation depth (r=0.95). CONCLUSIONS: Intraoperative online OCP could be an important safety feature to monitor the flap and residual stromal thicknesses during LASIK. The individual ablation depth and possible dehydration effects were also monitored continuously.

Published 24 December 2004 in J Cataract Refract Surg, 30(12): 2559-68.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Myopia Research Today. All Rights Reserved.



Myopia Research Today Archive:

Volume 1 (2004)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Myopia Books

The Art of LASIK

The Art of LASIK